    Description

    Schneider TeSys D Contactor
    Model Number: LC1D40AF7
    3P(3NO) / AC-3 ≤ 440 V 40 A / 110 V AC coil
    ※Please specify what voltage you need when ordering.
    Main
    range
    TeSys
    product name
    TeSys D
    product or component type
    Contactor
    device short name
    LC1D
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-1
    AC-3
    AC-4
    poles description
    3P
    pole contact composition
    3 NO
    [Ue] rated operational voltage
    Power circuit: <= 300 V DC
    Power circuit: <= 690 V AC 25...400 Hz
    [Ie] rated operational current
    40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    motor power kW
    9 kW at 400 V AC 50/60 Hz (AC-4)
    11 kW at 220...230 V AC 50/60 Hz (AC-3)
    18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
    22 kW at 415...440 V AC 50/60 Hz (AC-3)
    22 kW at 500 V AC 50/60 Hz (AC-3)
    30 kW at 660...690 V AC 50/60 Hz (AC-3)
    motor power HP (UL / CSA)
    3 hp at 115 V AC 50/60 Hz for 1 phase motors
    5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
    10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
    10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
    30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
    30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
    control circuit type
    AC 50/60 Hz
    control circuit voltage
    110 V AC 50/60 Hz
    auxiliary contact composition
    1 NO + 1 NC
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947
    overvoltage category
    III
    [Ith] conventional free air thermal current
    10 A (at 60 °C) for signalling circuit
    60 A (at 60 °C) for power circuit
    Irms rated making capacity
    140 A AC for signalling circuit conforming to IEC 60947-5-1
    250 A DC for signalling circuit conforming to IEC 60947-5-1
    800 A at 440 V for power circuit conforming to IEC 60947
    rated breaking capacity
    800 A at 440 V for power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current
    100 A - 1 s for signalling circuit
    120 A - 500 ms for signalling circuit
    140 A - 100 ms for signalling circuit
    72 A 40 °C - 10 min for power circuit
    165 A 40 °C - 1 min for power circuit
    320 A 40 °C - 10 s for power circuit
    720 A 40 °C - 1 s for power circuit
    associated fuse rating
    80 A gG at <= 690 V coordination type 1 for power circuit
    80 A gG at <= 690 V coordination type 2 for power circuit
    10 A gG for signalling circuit conforming to IEC 60947-5-1
    average impedance
    1.5 mOhm - Ith 60 A 50 Hz for power circuit
    [Ui] rated insulation voltage
    Power circuit: 600 V CSA certified
    Power circuit: 600 V UL certified
    Power circuit: 690 V conforming to IEC 60947-4-1
    Signalling circuit: 600 V CSA certified
    Signalling circuit: 600 V UL certified
    Signalling circuit: 690 V conforming to IEC 60947-1
    electrical durability
    1.4 Mcycles 60 A AC-1 at Ue <= 440 V
    1.5 Mcycles 40 A AC-3 at Ue <= 440 V
    power dissipation per pole
    5.4 W AC-1
    2.4 W AC-3
    Front cover
    With
    mounting support
    Rail
    Plate
    standards
    CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    product certifications
    CCC
    CSA
    GOST
    UL
    connections - terminals
    Control circuit: screw clamp terminals 1 cable(s) 1...4 mm² flexible with cable end
    Control circuit: screw clamp terminals 1 cable(s) 1...4 mm² flexible without cable end
    Control circuit: screw clamp terminals 1 cable(s) 1...4 mm² solid without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² flexible with cable end
    Control circuit: screw clamp terminals 2 cable(s) 1...4 mm² flexible without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1...4 mm² solid without cable end
    Power circuit: screw connectors 1 cable(s) 1…35 mm²flexible with cable end
    Power circuit: screw connectors 1 cable(s) 1…35 mm²flexible without cable end
    Power circuit: screw connectors 1 cable(s) 1…35 mm²solid without cable end
    Power circuit: screw connectors 2 cable(s) 1…25 mm²flexible with cable end
    Power circuit: screw connectors 2 cable(s) 1…25 mm²flexible without cable end
    Power circuit: screw connectors 2 cable(s) 1…25 mm²solid without cable end
    tightening torque
    Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
    Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm
    Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm
    operating time
    12...26 ms closing
    4...19 ms opening
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    mechanical durability
    6 Mcycles
    operating rate
    3600 cyc/h at <= 140 °F (60 °C)
    Complementary
    coil technology
    Without built-in suppressor module
    control circuit voltage limits
    0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
    0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
    0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
    1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
    inrush power in VA
    140 VA at 68 °F (20 °C) (cos ϕ 0.75) 60 Hz
    160 VA at 68 °F (20 °C) (cos ϕ 0.75) 50 Hz
    hold-in power consumption in VA
    13 VA at 68 °F (20 °C) (cos ϕ 0.3) 60 Hz
    15 VA at 68 °F (20 °C) (cos ϕ 0.3) 50 Hz
    heat dissipation
    4...5 W at 50/60 Hz
    auxiliary contacts type
    Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
    Type mirror contact (1 NC) conforming to IEC 60947-4-1
    signalling circuit frequency
    25...400 Hz
    minimum switching current
    5 mA signalling circuit
    minimum switching voltage
    17 V signalling circuit
    non-overlap time
    1.5 ms on de-energisation (between NC and NO contact)
    1.5 ms on energisation (between NC and NO contact)
    insulation resistance
    > 10 MOhm signalling circuit
    power range
    7…11 kW at 200…240 V 3 phases
    15…25 kW at 380…440 V 3 phases
    15…25 kW at 480…500 V 3 phases
    motor starter type
    Direct on-line contactor
    contactor coil voltage
    110 V AC
    Environment
    IP degree of protection
    IP20 front face conforming to IEC 60529
    protective treatment
    TH conforming to IEC 60068-2-30
    pollution degree
    3
    ambient air temperature for operation
    -40...60 °C
    ambient air temperature for storage
    -60...80 °C
    fire resistance
    1562 °F (850 °C) conforming to IEC 60695-2-1
    flame retardance
    V1 conforming to UL 94
    mechanical robustness
    Vibrations contactor open 2 Gn, 5...300 Hz
    Shocks contactor open 10 Gn for 11 ms
    Vibrations contactor closed 4 Gn, 5...300 Hz
    Shocks contactor closed 15 Gn for 11 ms
    height
    122 mm
    width
    555 mm
    depth
    120 mm
    product weight
    0.85 kg
    You can pick up from Fullerton, California or Piscataway, New Jersey or we will ship via UPS Ground.
    Contact us for exact shipping cost.
    Fullerton Office
    2320 E Valencia Dr
    Fullerton, CA 92831
    Piscataway Office
    244 N. Randolphville Road
    Piscataway, NJ 08854
    Payment
    Supra Machine Tool accepts: PayPal, Visa, Master Card, American Express, Money Orders, Cashier Checks, Wire Transfer as payment of goods purchased in our store. (Please send payment to
    2320 E Valencia Dr Fullerton, CA 92831
    ) All payments must be received within 7 business days. All buyers residing in California add 8.75% sales tax.
    Shipping and Handling
    Buyer pays the Shipping charge based on USPS Priority Mail or UPS Ground Shipping Charges. Orders being shipped to P.O. Boxes will be delivered by United States Postal Services (USPS). Note: Weight restrictions may apply in some cases. Orders under 150 lbs. can be shipped by U.P.S., freight prepaid or collect. Orders above 150 lbs. will be shipped by freight carrier. Supra Machine Tool offers a group of carriers that can quote you with an estimate of shipping charges for all items. Estimated delivery time by UPS is from 2 to 6 business days from the time the order is processed. International buyer pays the actual shipping charge + .50-.50 handling fees. International shipments of 150 lbs or more can be made by UPS International. Buyers are responsible for payment of all Shipping and Handling charges on all items.
    Terms and Conditions
    We guarantee the items are exactly as said in description. If you do not pay for them in the specified amount of time we have to file a non-paying complaint with eBay. Thank you for viewing. Supra Machine Tool appreciates your business very much.
    Please contact us if you have any questions.
    Visit our
    Supra Machine Tool E-bay Store
    for a wide selection of parts for milling machine, machining center, surface grinder, and engine lathes.